Description:
qPCR ProbesMaster UNG highROX is designed for quantitative real-time analysis of DNA samples using DNA probe based detection. The master mix is recommended for use with Dual Labeled Fluorescent Probes, e.g. TaqMan®, Molecular Beacons or FRET probes. It provides an easy-to-handle and powerful tool for quantification of sample DNA in a broad dynamic range of up to 6 orders of magnitude with exceptional sensitivity and precision.
The mix contains all reagents required for qPCR (except template, primer and labeled fluorescent probe) in a premixed 2x concentrated ready-to-use solution. The high specificity and sensitivity of the mix based on an optimized hot-start polymerase. Its activity is blocked by antibody at ambient temperature and switched on automatically at the onset of the initial denaturation. The thermal activation prevents the extension of nonspecifically annealed primers and primer-dimer formation at low temperatures during PCR setup.
The mix contains UNG (Uracil-N-Glycosylase) and dUTP instead of dTTP to eliminate carry-over contamination of DNA from previous PCR reactions. The UNG treatment at the onset of thermal cycling removes uracil residues from dU-containing DNA and prevents it from serving as template.
The reaction chemistry of the kit is optimized for instruments that are compatible with the evaluation of a high ROX reference signal.

ROX reference dye:
The qPCR ProbesMaster with highROX contains 500 nM ROX passive reference dye in the final assay. The dye does not take part in the PCR reaction but allows to normalize for non-PCR related signal variation and provides a baseline in multiplex reactions.

Dual-labeled DNA probes:
Real-time PCR technology based on dual-labeled DNA probes provides a high sensitive and high specific PCR system with multiplexing capability. It requires two standard PCR primers and the DNA probe that hybridizes to an internal part of the amplicon. The sequence of the dual-labeled DNA probe should avoid secondary structure and primer-dimer formation.

Content:
qPCR ProbesMaster UNG highROX (red cap)
Hot Start Polymerase Ab+, UNG, dATP, dCTP, dGTP, dUTP, KCl, (NH4)2SO4, MgCl2, additives and stabilizers, 1 μM ROX

PCR-grade water


Preparation of the qPCR master mix:
The preparation of a master mix is crucial in quantitative PCR reactions to reduce pipetting errors. Prepare a master mix of all components except template as specified. A reaction volume of 20-50 μl is recommended for most real-time instruments. Prepare 13 volumes of master mix for 12 samples or a triple-set of 4 samples. Pipet with sterile filter tips and minimize the exposure of the labeled DNA probe to light. Perform the setup in an area separate from DNA preparation or analysis. No-template controls should be included in all amplifications.

component20 μl
assay
50 μl
assay
final conc.
qPCR ProbesMaster
with UNG/highROX
10 μl25 μl1x
primer
forward
(10 μM)1)
0.6 μl1.5 μl300 nM
primer
reverse
(10 μM)1)
0.6 μl1.5 μl300 nM
dual-labeled probe
(10 μM)2)
0.4 μl1 μl200 nM
template DNAx μlx μl<500 ng/assay
PCR-grade waterfill up to
20 μl
fill up to
50 μl
-

1) The optimal concentration of each primer may vary from 100 to 500 nM.
2) Optimal results may require a titration of DNA probe concentration between 50 and 800 nM.

Dispensing the master mix:
Vortex the master mix thoroughly to assure homogeneity and dispense the mix into real-time PCR tubes or wells of the PCR plate.

Addition of template DNA:
Add the remaining x μl of sample/template DNA to each reaction vessel containing the master mix and cap or seal the tubes/plate. Do not exceed 500 ng DNA per reaction as final concentration. Tubes or plates should be centrifuged before cycling to remove possible bubbles.
Recommended cycling conditions:

UNG treatment3)50 °C2 min1x
Initial
denaturation and
polymerase activation
95 °C2 min1x
Denaturation95 °C15 sec35-45x
Annealing and
elongation
60-65 °C4)1 min5)35-45x

3) Cycling step 1 is only required if an UNG (Uracil-N-Glycosylase) treatment is applied.
4) The annealing temperature depends on the melting temperature of the primers and DNA probe used.
5) The elongation time depends on the length of the amplicon. A time of 1 min for a fragment of up to 500 bp is recommended.

For optimal specificity and amplification an individual optimization of the recommended parameters, especially of the annealing temperature may be necessary for each new combination of template DNA, primer pair and DNA probe.