DIG 3'-End Oligonucleotide Labeling Kit with Digoxigenin-11-ddUTP
For research use only.
Description:
DIG 3'-End Oligonucleotide Labeling Kit with Digoxigenin-11-ddUTP contains all reagents (except oligonucleotide template to be labeled and materials for Digoxigenin detection) required for efficient 3'-End digoxigenylation of DNA oligonucleotides (length: 20 -100 bp, 5 pmol per reaction).
The labeling principle is based on Terminal deoxynucleotidyl Transferase (TdT) that template-independently transfers 1 Digoxigenin-11-ddUTP to the 3'-OH group of ssDNA (e.g. an oligonucleotide) in the presence of CoCl2. It is similar to the principle of DIG Oligonucleotide 3'-End DNA Labeling Kit, 2nd Generation (Roche).
The resulting 3'-End digoxigenylated oligonucleotides are ideally suited for applications involving sequence-specific protein binding or hybridiziation such as EMSA, Northern or Southern blots. Compared to internal, random digoxigenylated probes, Digoxigenin is located at the 3'-End only and less likely interferes with probe binding.
TdT possesses a preference for single-stranded DNA (ssDNA) over dsDNA with 3'-overhangs or blunt ends. For the preparation of labeled dsDNA complexes, label each complementary oligonucleotide separately and anneal them before use.
Shipping: shipped on gel packs
Storage Conditions: store at -20 °C
avoid freeze/thaw cycles
Shelf Life: 12 months
Content:
Terminal Deoxynucleotidyl Transferase (TdT)
30 μl (20 U/μl) in 100 mM potassium acetate (pH 6.8), 2 mM 2-mercaptoethanol, 0.01% Triton X-100 (v/v) and 50% glycerol (v/v)
5x TdT Reaction Buffer
400 μl containing 1 M potassium cacodylate, 0.125 M Tris, 0.05% Triton X-100 (v/v), 5 mM CoCl2, pH 7.2
Digoxigenin-11-ddUTP
25 μl (1 mM )
Unlabeled Control Oligonucleotide (60 bp)
250 μl, 1 μM in 1x TE Buffer, pH 7.6
3'-Digoxigenin-labeled Control Oligonucleotide (60 bp)
130 μl, 1 μM in 1x TE Buffer, pH 7.6
PCR-grade H2O
12.5 ml
1x TE Buffer, pH 7.6
100 ml containing 10 mM Tris-HCl, 1 mM EDTA, pH 7.6
Stop Buffer
400 μl, 0.5 M EDTA solution, pH 8
1. Preparation of working solutions
1.1 Preparation of Digoxigenin-11-ddUTP working solution (10 μM)
- Thaw 1 mM Digoxigenin-11-ddUTP solution on ice, voretex and spin-down briefly.
- Prepare a 1: 100 dilution with PCR-grade H2O to achieve a final concentration of 10 μM (e.g. 1 μl of 1 mM Digoxigenin-11-ddUTP + 99 μl PCR-grade H2O).
- Keep working solution (10 μM) on ice until use (see 2.).
- Prepare Digoxigenin-11-ddUTP working solution (10 μM) freshly for each experiment. Do not store for subsequent use.
2. 3' End Oligonucleotide labeling reaction
- Store all components except of TdT on ice until use.
- Store TdT at -20°C until use.
- Final Assay volume: 50 μl
- Template requirements: oligonucleotide/ssDNA purified by HPLC or gel electrophoresis, 20 – 100 bp
- Add all components on ice exactly in the order listed below.
- Mix reaction gently by pipetting up and down. Do not voretex!
- Incubate 30 min at 37 °C.
- Add 1 μl Stop Buffer (0.5 M EDTA solution, pH 8) to stop each reaction.
- Store reactions on ice for subsequent use (see 3.) or -20 °C for long-term storage.
| Component | Volume | Final concentration | Final molar amount |
|---|---|---|---|
| PCR grade H2O | 31.5 μl | n/a | n/a |
| 5x TdT Reaction Buffer | 10 μl | 1x | n/a |
| oligo-nucleotide template (1 μM) | 5 μl | 100 nM | 5 pmol |
| Digoxigenin-11-ddUTP (10 μM) (see 1.1) | 2.5 μl | 0.5 μM | 50 pmol |
| TdT (20 U/μl) | 1 μl | 0.4 U/μl | 20 U |
| Total volume | 50 μl |
3. Estimation of Digoxigenin labeling degree
Quantification of Digoxigenin labeling degree is essential for reproducible downstream results. An oligonucleotide dilution series is immobilized on a positively-charged membrane (Dot Blot) followed by an indirect detection of the Digoxigenin moiety using an anti-Digoxigenin-alkaline phosphatase (AP) conjugate.
Recommended oligonucleotide starting amount for chemiluminescent detection: 100 fmol
The following reagent amounts (3.1 – 3.5) are calculated for an oligonucleotide starting amount of 100 fmol.
3.1 Preparation of Unlabeled control oligonucleotide (Unlab. oligo)
working solution (500 nM)
- Thaw 1 μM unlabeled control oligonucleotide solution on ice, voretex and spin-down briefly.
- Prepare a 1:2 dilution with 1x TE Buffer, pH 7.6 to achieve a final concentration of 500 nM (e.g. 5 μl of 1 μM unlabeled control oligonucleotide + 5 μl 1x TE Buffer, pH 7.6).
- Keep the working solution (500 nM) on ice until use (see 2.).
- Prepare unlabeled control oligonucleotide working solution (500 nM) freshly for each experiment. Do not store for subsequent use.
3.2 Preparation of 3'-Digoxigenin-labeled control oligonucleotide
(3'-DIG oligo) working solution (500 nM)
- Thaw 1 μM 3'-Digoxigenin-labeled control oligonucleotide solution on ice, voretex and spin-down briefly.
- Prepare a 1:2 dilution with 1x TE Buffer,pH 7.6 to achieve a final concentration of 500 nM (e.g. 5 μl of 1 μM 3'-Digoxigenin-labeled control oligonucleotide solution + 5 μl 1x TE Buffer, pH 7.6).
- Keep the working solution (500 nM) on ice until use (see 2.)
- Prepare 3'-Digoxigenin-labeled control oligonucleotide working solution (500 nM) freshly for each experiment. Do not store for subsequent use.
3.3 Preparation of Digoxigenin oligonucleotide standard solutions
(50 fmol/μl)
- Prepare Digoxigenin oligonucleotide standard solutions (S1 – S5) with varying degrees of oligonucleotide digoxigenylation as follows.
- Total oligonucleotide concentration (S1-S5): 50 fmol/μl
- Degree of dioxygenylation: S1=100 %, S2=75 %, S3= 50 %, S4= 25 %, S5= 0 %
- Voretex and spin-down briefly.
| S1 | S2 | S3 | S4 | S5 | |
|---|---|---|---|---|---|
| 3'-DIG oligo (500nM) (s. 3.2) | 2 μl | 1.5 μl | 1 μl | 0.5 μl | 0 μl |
| Unlab. oligo (500nM) (s. 3.1) | 0 μl | 0.5 μl | 1 μl | 1.5 μl | 2 μl |
| 1x TE Buffer pH 7.6 | 8 μl | 8 μl | 8 μl | 8 μl | 8 μl |
| Total Volume | 10 μl | 10 μl | 10 μl | 10 μl | 10 μl |
3.4 Preparation of sample dilutions (50 fmol/μl)
- Dilute sample labeling reaction(s) (see 1) 1:2 to a final oligonucleotide concentration of 50 nM (e.g. 5 μl sample labeling reaction + 5 μl 1x TE Buffer, pH 7.6.)
- Voretex and spin-down briefly.
3.5 Preparation oligonucleotide standard and sample dilution series
- Transfer 10 μl of each Digoxigenin oligonucleotide standard solution S1 – S5 (see 2.1) to well A1 – A5 of a low absorption 96-well PCR plate, respectively (e.g. 96-well Multiply® PCR plate, Sarstedt, #72.1979.102).
- Transfer 10 μl of sample dilution(s) (see 2.2) to the remaining A" wells (A6 to A…)
- Prepare a two-fold dilution series with 1x TE Buffer as follows:
| 1 | 2 | 3 | 4 | 5 | 6 | |
|---|---|---|---|---|---|---|
| A | 10μl of S1 | 10μl of S2 | 10μl of S3 | 10μl of S4 | 10μl of S5 | 10μl sample |
| B | 5μl A1 + 5μl TE | 5μl A2 + 5μl TE | 5μl A3 + 5μl TE | 5μl A4 + 5μl TE | 5μl A5 + 5μl TE | 5μl A6 + 5μl TE |
| C | 5μl B1 + 5μl TE | 5μl B2 + 5μl TE | 5μl B3 + 5μl TE | 5μl B4 + 5μl TE | 5μl B5 + 5μl TE | 5μl B6 + 5μl TE |
| D | 5μl C1 + 5μl TE | 5μl C2 + 5μl TE | 5μl C3 + 5μl TE | 5μl C4 + 5μl TE | 5μl C5 + 5μl TE | 5μl C6 + 5μl TE |
| E | 5μl D1 + 5μl TE | 5μl D2 + 5μl TE | 5μl D3 + 5μl TE | 5μl D4 + 5μl TE | 5μl D5 + 5μl TE | 5μl D6 + 5μl TE |
| F | 5μl E1 + 5μl TE | 5μl E2 + 5μl TE | 5μl E3 + 5μl TE | 5μl E4 + 5μl TE | 5μl E5 + 5μl TE | 5μl E6 + 5μl TE |
3.6 Dot Blot and UV crosslinking
- Equilibrate a positively-charged membrane of appropriate size for at least 10 minutes in 1x TE Buffer, pH 7.6 (e.g. Biorad Zeta-Probe® Membrane, #1620159).
- Place the equilibrated membrane onto a clean dry Whatman® paper. Allow excess buffer to absorb into the membrane, but do not let the membrane dry out.
- Spot 2 μl of each dilution onto the membrane.
| 3'-OH [fmol] | 100% DIG | 75% DIG | 50% DIG | 25% DIG | 0% DIG | Sample |
|---|---|---|---|---|---|---|
| 100 | 2μl A1 | 2μl A2 | ... | ... | ... | 2μl A6 |
| 50 | 2μl B1 | ... | ... | |||
| 25 | ... | |||||
| 12.5 | ||||||
| 6.25 | ||||||
| 3.125 |
- Allow samples to absorb into the membrane.
- Immediately fix the oligonucleotide to the membrane by crosslinking with UV-light using a commercial UV-light crosslinking instrument according to the manufacturers instructions (e.g. 120 mJ/cm2, 254 nm bulbs, 45-60 second exposure).
- Proceed immediately with detection (see 3.7) or store the membrane dry at room-temperature.
3.7 Digoxigenin detection with anti-Digoxigenin-Alkaline Phosphatase (AP)
- Perform Digoxigenin detection with an appropriate anti-Digoxigenin-alkaline phosphatase (AP) conjugate followed by chemiluminescent.
- Compare spot intensities of sample lanes to those of control oligonucleotide template and Digoxigenin oligonucleotide standard.
Please note: Digoxigenin labeling degree may vary depending on the template (e.g. purity, length or overall sequence).
"