Your Basket/Online Quote
Items: 0 (0,00 €)
» Search & Order
» Sign in / Register
Robust real-time RT-PCR master mix with green-fluorescent DNA stain
for highly sensitive and specific amplification directly from tissue, swabs or blood
| Cat. No. | Amount | Price (EUR) | Buy / Note |
|---|---|---|---|
| PCR-532S | 2 x 1,25 ml (250 reactions x 20 μl) | 382,10 | Add to Basket/Quote Add to Notepad |
| PCR-532L | 10 x 1,25 ml (1250 reactions x 20 μl) | 1.528,60 | Add to Basket/Quote Add to Notepad |
For general laboratory use.
Please centrifuge briefly before opening (volume ≤2 ml).
Shipping: shipped on gel packs
Storage Conditions: store dark at -20 °C
avoid freeze/thaw cycles, store dark
stable at 4 °C for up to 4 weeks
Shelf Life: 12 months
Form: liquid
Concentration: 2x
Description:
SCRIPT Direct RT-qPCR GreenMaster is designed for quantitative real-time analysis of target RNA directly from animal- or plant tissue, swabs and blood. The mix allows robust amplification avoiding the requirement of any prior RNA purification procedures based on a green-fluorescent DNA stain that is structurally similar to SYBR® GREEN.
It allows fast and easy quantification of sample RNA over a wide dynamic range with exceptional sensitivity and precision.
The mix contains all reagents required for RT-qPCR (except template and primers) in a premixed 2 x concentrated ready-to-use solution. High robustness, reliability and sensitivity of the mix are based on a genetically engineered reverse transcriptase and an antibody-blocked hot start polymerase in combination with an optimized and well-balanced buffer system.
The mix ensures fast and easy preparation with a minimum of pipetting steps and is specially recommended for:
ROX Reference Dye
The mix can also be used in combination with ROX reference dye (#PCR-351) in PCR instruments that are compatible with the evaluation of the ROX signal.
Content:
SCRIPT Direct RT-qPCR GreenMaster
2x conc. mix of Reverse Transcriptase, antibody-blocked Hot Start polymerase, dNTPs, green-fluorescent DNA stain, reaction buffer, additives and stabilizers
Direct Extraction Buffer
5x conc.
Please handle with care and wear personal protective equipment!
PCR-grade Water
Procedure
Before starting, take reagents out from fridge and allow to thaw completely. Vortex all reagents briefly and spin down the liquids.
1. Sample preparation
1.a Blood Samples / Liquid Samples
1.b Samples from nasal or throat swabs
1.c Samples from Animal or Plant Tissue
| Sample size (diameter) | 1-2 mm | 3-4 mm | 5-8 mm |
| 1x Direct Extraction Buffer | 50 μl | 100 μl | 200 μl |
2. Preparation of the RT-qPCR Assay
Preparation of a master mix is crucial in quantitative PCR reactions to reduce pipetting errors. Prepare a master mix of all components except template as specified below. A reaction volume of 20-50 μl is recommended for most real-time instruments. Pipet with sterile filter tips and minimize the exposure of the labeled DNA probe to light. Perform the setup in an area separate from DNA preparation or analysis. No-template controls should be included in all amplifications.
| component | stock conc. | final conc. | 20 μl assay | 50 μl assay |
| SCRIPT Direct RT-qPCR GreenMaster | 2x | 1x | 10 μl | 25 μl |
| Extracted Sample | - | - | 1-2 μl | 2-5 μl |
| Forward Primer 11) | 10 μM | 300 nM | 0.6 μl | 1.5 μl |
| Reverse Primer 11) | 10 μM | 300 nM | 0.6 μl | 1.5 μl |
| ROX Reference Dye #PCR-351 2) | 25 μM | 500 nM | 0.4 μl | 1 μl |
| PCR-grade water | - | - | fill up to 20 μl | fill up to 50 μl |
Mix the tubes briefly and spin down to remove bubbles.
3. RT-PCR Cycling
Switch on the real-time PCR cycler and set all cycling parameters as recommended in the table below. Place the vials into the instrument and start the program.
| Reverse transcription3) | 50-55 °C | 10-15 min | 1x |
| Initial denaturation | 95 °C | 5 min | 1x |
| Denaturation Annealing Elongation | 95 °C 60-65 °C 4) 72 °C | 15 sec 20-30 sec 30-60 sec5) | 35-45x |
To obtain optimal specificity and amplification results an individual optimization of the recommended parameters is recommended for each particular sample/primer pair.
4. Data Analysis
® SYBR is a trademark of Molecular Probes, Inc.
5x Extraction Buffer
Hazard pictograms:
Signal word: Warning
Hazard statements:
H315 Causes skin irritation.
H319 Causes serious eye irritation.
Precautionary statements:
P280 Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/....
P302 + P352 IF ON SKIN: Wash with plenty of water/…
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P321 Specific treatment (see … on this label).
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
BIOZ Product Citations: